Titel:
|
Thermoacoustic-stirling heat pump for domestic applications
|
|
Auteur(s):
|
|
|
Gepubliceerd door:
|
Publicatie datum:
|
ECN
Efficiency & Infrastructure
|
1-9-2010
|
|
ECN publicatienummer:
|
Publicatie type:
|
ECN-M--10-071
|
Conferentiebijdrage
|
|
Aantal pagina's:
|
Volledige tekst:
|
8
|
Download PDF
(297kB)
|
Gepresenteerd op: ASME 2010 3rd Joint US-European Fluids Engineering Summer Meeting and 8th International Conference on Nanochannels, Microchannels, and Minichannels, Montreal, Canada, 1-5 augustus 2010.
Samenvatting:
Domestic heating contributes to a significant amount of energy usage in the Netherlands. Due to scarce energy resources, attention to develop new and efficient technologies is increasing. At ECN, a burner driven heat pump employing thermoacoustic technology is being developed for possible applications in households and offices. The desired temperature lift is from 10 °C to 80 °C. As a first step the heat pump is driven by a linear motor. Measurements and performance analysis of the heat pump are presented in this paper. The heat pump has a coefficient of performance which is the ratio of heat produced to the work input of 1.38 when operating between 10 °C to 80 °C. The performance relative to maximum possible Carnot value is 26.5 %.