Publicaties

Skip Navigation Links.
Recent verschenen
Collapse per documenttypeper documenttype
Expand per Unitper Unit
Expand per Clusterper Cluster

Zoeken naar publicaties:
Beperk het zoeken tot de velden:

ECN publicatie:
Titel:
Analyse meetresultaten PV-installatie te Zandvoort: januari - december1995 (tussenrapportage)
 
Auteur(s):
 
Gepubliceerd door: Publicatie datum:
ECN 1996
 
ECN publicatienummer: Publicatie type:
ECN-C--96-006 ECN rapport
 
Aantal pagina's: Volledige tekst:
46 Download PDF  (1175kB)

Samenvatting:
The results of measurements, executed at the PV-installation on the roof of a zero-energy house in Zandvoort, Netherlands, are analyzed. The system comprises 64 PV-panels and two grid-connected DC/AC inverters. The total installed capacity is 3295 Wp. The solar radiation on the reference cells was circa 1208 kWh/m2 within the measuring period of the year 1995. The energy yield of the inverters' output to the grid was 2876 kWh. The efficiency of the inverter was more than expected. The standard yield is 873 kWh/kWp. The yield factor is 0.726. The annual average efficiency of the inverters is 90.4%, according to the expectations. The reliability of the panels, the cables and other components is good. In the monitoring period one inverter did not perform well during six weeks.
1 figs., 6 tabs., 4 refs., 7 appendices


Terug naar overzicht.