Publicaties

Skip Navigation Links.
Recent verschenen
Collapse per documenttypeper documenttype
Expand per Unitper Unit
Expand per Clusterper Cluster

Zoeken naar publicaties:
Beperk het zoeken tot de velden:

ECN publicatie:
Titel:
Analyse meetresultaten PV-woningen te Heerhugowaard: periode1994
 
Auteur(s):
 
Gepubliceerd door: Publicatie datum:
ECN 1995
 
ECN publicatienummer: Publicatie type:
ECN-C--95-116 ECN rapport
 
Aantal pagina's: Volledige tekst:
70  Niet beschikbaar.

Samenvatting:
Data from measurements, carried out in 1994, on 4 roof-integratedgrid-connected photovoltaic systems of 4 single-family dwellings in Heerhugowaard, Netherlands, are presented. The yield factors vary from 0.60 to 0.75. The energetic conversion efficiency of the SMA inverters is circa 83% and the energetic conversion efficiency of the so-called Victron inverters is circa 91%. Also, attention is paid to the different performances of the three configurations of the installation: SMA inverters in cascade, SMA inverters parallel, and Victron inverters in stand-alone operation. The Maximum Power Point Trackers (MPPT) of the SMA inverters appear to be very sensitive for varying radiations and super-sensitive for high ambient temperatures of the inverter. Also, the DC-efficiency of the systems with Victron inverters is not efficient within the radiation area of 50-300 W/m2. 1 figs., 7 tabs., 7 refs., appendices


Terug naar overzicht.