Publicaties

Skip Navigation Links.
Recent verschenen
Collapse per documenttypeper documenttype
Expand per Unitper Unit
Expand per Clusterper Cluster

Zoeken naar publicaties:
Beperk het zoeken tot de velden:

ECN publicatie:
Titel:
Thermal and electrical yield of a combi-panel
 
Auteur(s):
Zondag, H.A.; Helden, W.G.J. van; Zolingen, R.J.C. van; Vries, D.W. de; Steenhoven, A.A. van
 
Gepubliceerd door: Publicatie datum:
ECN Energie in de Gebouwde Omgeving en Netten 1-12-2002
 
ECN publicatienummer: Publicatie type:
ECN-RX--02-064 Conferentiebijdrage
 
Aantal pagina's: Volledige tekst:
6 Download PDF  (531kB)

Gepresenteerd op: ISES Solar World Congress, Jerusalem, Israel, 4-9 juli 1999.

Samenvatting:
A first, non-optimised prototype of a combi-panel was built of a PV-laminateand a sheet-and-tube absorber. The thermal efficiency at zero reduced temperature was found to be 54%, along with 8.5% electrical efficiency. The results of the measurements were used to verify the results of the simulations. It was concluded that the simulations and the measurements corresponded sufficiently well. Then, the simulations were used to find the annual efficiency of a PV/T-system that was used for hot-water production in a Dutch houshold, for which 33% themal and 6.7 electrical efficiency was found. Finally, the simulations were used to quantify the contribution of the various loss terms to the reduction in thermal efficiency of a PV/T-system with respect to a thermal collector.


Terug naar overzicht.